flexible endoscope medical device repair training
"
T-F0025 নমনীয় এন্ডোস্কোপ মেরামত টুল জন্য Pentax EB-1970UK Fujinon EG-250WR5 EB-270S
Product Description 1. Introduction T-F0025 Repair tool for Pentax EB-1970UK EC-3890Zi Olympus JF-260V ENF-P4 Fujinon EG-250WR5 EB-270S Flexible Endoscope Brand-new Perfectly repair flexible endoscope without scratch 2. Characteristics and Advantages Number:T-F0025 Features: Durable, Portable, Multi-functional Advantages: High Quality Materials, Precise Design, Easy To Use Main Material: Aluminum Alloy Weight: 5KG 3.Functions: For flexible endoscope rubber disassembly and
T-F0020 নমনীয় এন্ডোস্কোপ মেরামত সরঞ্জাম জন্য OLYMPUS OTV-S7PROH-HD-12E Q OTV-S7PROH-HD অটোক্লেভযোগ্য
Product Description 1. Introduction T-F0020 Repair tool for OLYMPUS OTV-S7PROH-HD-12 OTV-S7PROH-HD-12E /Q OTV-S7PROH-HD Autoclavable Camera Head Brand-new Perfectly repair camera head without scratch 2.Characteristics and Advantages Number:T-F0020 Features: Durable, Portable, Multi-functional Advantages: High Quality Materials, Precise Design, Easy To Use Main Material: Stainless Steel Weight: 0.5KG 3.Functions: Disassembly and assembly 4.Quality and Reliability High-quality
মেরামতের জন্য কার্ল স্টর্জ ২৭০০৫বিএ এন্ডোস্কোপ
Karl Storz 27005BA endoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. ►Problem & Solutoin
Karl Storz 27005BA Cystoscope for repair
Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. ►Problem & Solutoin
মেরামত মেডিকেল ডিভাইস যন্ত্রাংশের জন্য C5-2 কনভেক্স প্রোব
C5-2 Convex Probe For Repair ► Brief Description Fault: Strain relief damage, cable broken. Solution: Replace strain relief, repair cable. ►Problem & Solutoin Model C5-2 Convex Fault Strain relief damage, cable broken Solution Replace strain relief, repair cable ► Common Issues with C5-2 Probes Dead or flickering elements (image dropouts, black lines) Cable damage (broken wires near the connector or handle) Lens damage (cracks, delamination, or wear) Acoustic array failure
মেরামতের জন্য GE 4C-RS পেটের প্রোব
GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS Probe Image dropouts / Black lines Acoustic lens damage Cable damage Connector damage Oil leakage If your instrument has any of the above problems or others, please feel free to
S5-2 মেরামতের জন্য হার্ট প্রোব
S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain relief ► Common issues with S5-2 Cardiac probe Poor or blurry images Constant noise or static Color streaking or intermittent artifacts Cracked or dried-out lens Cable or strain
Olympus TJF-160VR এর জন্য নমনীয় এন্ডোস্কোপ বডি কভার
Flexible Endoscope body cover for Olympus TJF-160VR ► Brief Description The body cover of the Olympus TJF-160VR is a critical component designed to ensure ergonomic comfort, durability, and protection for the endoscope's operational controls during clinical procedures. It is engineered to withstand frequent disinfection cycles and mechanical stress while maintaining optimal functionality. ► Features Ergonomic Design Protection and Durability Operational Efficiency Hygiene
Cf-H290i অলিম্পাস কলোনস্কোপ সিসিডি অবজেক্টিভ লেন্স ফ্লেক্সিবল এন্ডোস্কোপের অংশ
Detail CCD Objective lens for Olympus CF-H290I Colonoscope Spare parts for Olympus GIF-HQ290,GIF-H290,GIF-100,GIF-130,GIF-140,GIF-160 ,GIF-H260,GIF-Q160,GIF-Q180,GIF-Q260 ,GIF-Q30,GIF-V,GIF-V2,GIF-V70,GIF-XQ140,GIF-XQ20,GIF-XQ230,GIF-XQ240,GIF-XQ260,GIF-XP260,GIF-Q260//CF-HQ290I,CF-140,CF-140I,CF-200L,CF-240I,CF-40I,CF-H260AI,CF-H260AZI,CF-LB3W,CF-Q160I,CF-Q240I ,CF-Q240L,CF-Q260AI,CF-V70I,CF-V70,CF-VI//JF-240,TJF-140R,TJF-200//BF-1T180 ,BF-1T240,BF-1T260,BF-160,BF-240,BF